Validation of energy expenditure evaluation by SenseWear Armband by direct comparison with indirect calorimetry.

  • Energy expenditure evaluation in humans and non-human primates by SenseWear Armband.
  • Accuracy of the SenseWear Armband™ during ergocycling.
  • Measuring energy expenditure in cardiac patients using the Body Media Armband versus indirect calorimetry.
  • Energy Expenditure in Adolescents With Cerebral Palsy: Comparison of the SenseWear Armband and Indirect Calorimetry.
  • Validity of SenseWear® Armband v5.2 and v2.2 for estimating energy expenditure.
  • #Sensewear professional 8.1 pro#

    When exercise-specific algorithms are used, the SenseWear Pro Armband provides an accurate estimate of energy expenditure when compared to indirect calorimetry during exercise periods examined in this study. CONCLUSIONS: It appears that it is necessary to apply exercise-specific algorithms to the SenseWear Pro Armband to enhance the accuracy of estimating energy expenditure during periods of exercise. At the request of the investigators, exercise-specific algorithms were developed by the manufacturer and applied to the data that resulted in nonsignificant differences in total energy expenditure between indirect calorimetry and the SenseWear Pro Armband of 4.6 +/- 18.1 kcal (2.8 +/- 9.4%), 0.3 +/- 11.3 kcal (0.9 +/- 10.7%), 2.5 +/- 18.3 kcal (0.9 +/- 11.9%), and 3.2 +/- 8.1 kcal (3.8 +/- 9.9%) for the walk, cycle ergometer, step, and arm ergometer exercises, respectively. RESULTS: : When a generalized proprietary algorithm was applied to the data, the SenseWear Pro Armband significantly underestimated total energy expenditure by 14.9 +/- 17.5 kcal (6.9 +/- 8.5%) during walking exercise, 32.4 +/- 18.8 kcal (28.9 +/- 13.5%) during cycle ergometry, 28.2 +/- 20.3 kcal (17.7 +/- 11.8%) during stepping exercise, and overestimated total energy expenditure by 21.7 +/- 8.7 kcal (29.3 +/- 13.8%) during arm ergometer exercise (P < or = 0.001). Estimated energy expenditure from the SenseWear Pro Armband was compared with energy expenditure determined from indirect open-circuit calorimetry, which served as the criterion measure.

    sensewear professional 8.1

    Subjects wore the SenseWear Pro Armband on the right arm, and energy expenditure was estimated using proprietary equations developed by the manufacturer. METHODS: : Forty subjects (age = 23.2 +/- 3.8 yr body mass index = 23.8 +/- 3.1 kg x m) performed four exercises (walking, cycling, stepping, arm ergometry) with each exercise lasting 20-30 min and workload increasing at 10-min intervals. N2 - PURPOSE: To assess the accuracy of the SenseWear Pro Armband for estimating energy expenditure during exercise. JF - Medicine and science in sports and exercise T1 - Evaluation of the SenseWear Pro Armband to assess energy expenditure during exercise.